Enter your room dimensions and humidity conditions below. The calculator uses AHAM guidelines combined with IICRC S500 restoration standards to return the minimum pint-per-day capacity for your space — then adjusts for ceiling height, space type, and temperature.
Results include specific model recommendations from our catalog. All prices shown — no quote needed.
Find the right dehumidifier capacity for your space in under 60 seconds. Our calculator uses AHAM guidelines combined with IICRC S500 restoration standards.
Enter the length, width, and ceiling height of your space
Select the condition that best describes your space
Where will the dehumidifier be used?
What's the typical temperature in the space?
Dehumidifier Sizing Tips
Size Up for Tough Conditions
For water damage or extremely humid climates, choose a unit 20-30% larger than calculated for faster drying.
LGR vs Conventional
LGR (Low Grain Refrigerant) dehumidifiers are more efficient and can achieve lower humidity levels. Best for restoration work.
Consider Multiple Units
For spaces over 2,500 sq ft, multiple smaller units often work better than one large unit for better air circulation.
Drainage Options
For continuous operation, choose a unit with gravity drain or condensate pump for hands-free moisture removal.
How We Calculate
Our calculator uses AHAM guidelines combined with IICRC S500 restoration standards. Base capacity is determined by square footage, then adjusted for humidity severity (+25-50%), space type factors, and ceiling height.
Need Help Choosing?
Our team has real restoration experience. Call us for personalized recommendations.
Building a fleet? Ask about volume pricing →
Sizing other equipment? Try the air scrubber calculator, the water damage equipment calculator, or the floor scrubber selector.
How to Size a Dehumidifier — The Method Behind the Calculator
The AHAM standard rates dehumidifiers at 80°F and 60% relative humidity. That's ideal lab conditions — not a flooded basement at 55°F or a crawl space in January. Real-world extraction runs 30–50% lower than the rated pint capacity depending on temperature and humidity level. Our calculator accounts for this by applying IICRC S500 correction factors before showing you a result.
Step 1 — Calculate base capacity from square footage
The AHAM baseline: 1 pint per 24 hours per 50 sq ft at moderately damp conditions (50–60% RH). A 1,000 sq ft basement at moderate humidity needs roughly 20 pints/day as a starting point. Compare dehumidifiers sized for basements at that capacity.
Step 2 — Adjust for humidity severity
- Moderately damp (50–60% RH): Use base capacity
- Very damp (60–70% RH): Add 25% — musty smell, damp spots visible
- Wet (70–80% RH): Add 50% — sweating walls, condensation
- Extremely wet / water damage (80%+ RH): Double the base — standing water, active drying project
Step 3 — Adjust for space type and ceiling height
Basements and crawl spaces have limited air circulation and ground moisture infiltration — add 10–15%. Spaces with ceilings above 8 ft hold more moisture volume; multiply by the ceiling height ratio (actual height ÷ 8). Warehouse and industrial spaces with large doors or loading docks add 20% for air infiltration.
Step 4 — Check temperature
Below 60°F, standard refrigerant dehumidifiers lose efficiency rapidly and can ice up. For cold basements, crawl spaces in winter, or any space below 55°F: use a desiccant dehumidifier (like Bry-Air models) or an LGR unit rated for low-temperature operation. LGR (Low Grain Refrigerant) dehumidifiers maintain efficiency 10–15% better than standard refrigerant units at the same conditions.
Dehumidifier Size Chart — Square Footage to Pints
A fast reference for standard 8 ft ceilings and general-purpose spaces. Find your room size, read across to your humidity condition, and you have the minimum AHAM pint-per-day capacity. Below-grade, high-ceiling, or cold spaces need more — run those through the calculator above, which applies the Step 3–4 corrections for you.
| Room size | Moderately Damp 50–60% RH |
Very Damp 60–70% RH |
Wet 70–80% RH |
|---|---|---|---|
| 300 sq ft | 6 pints/day | 8 pints/day | 9 pints/day |
| 500 sq ft | 10 pints/day | 13 pints/day | 15 pints/day |
| 800 sq ft | 16 pints/day | 20 pints/day | 24 pints/day |
| 1,000 sq ft | 20 pints/day | 25 pints/day | 30 pints/day |
| 1,200 sq ft | 24 pints/day | 30 pints/day | 36 pints/day |
| 1,500 sq ft | 30 pints/day | 38 pints/day | 45 pints/day |
| 2,000 sq ft | 40 pints/day | 50 pints/day | 60 pints/day |
Minimum AHAM-rated capacity for an 8 ft ceiling before Step 3–4 corrections. Basements and crawl spaces add 10–15%; ceilings over 8 ft scale by height ÷ 8; active water damage doubles the base (IICRC S500). Dehumidifiers are sold in fixed sizes (20, 30, 50, 70, 90+ pints) — round up to the next available unit.
Commercial Dehumidifier Sizing for Large Spaces (2,000+ sq ft)
Commercial dehumidifier sizing works differently from home sizing. Consumer sizing charts and most online calculators stop at around 2,000 sq ft, but warehouses, gyms, indoor pools, storage facilities, and restoration jobsites need capacity those charts never cover. For a large space, size on total moisture load — square footage, humidity severity, ceiling height, and use — not a single "room size" number. Below ~55°F, refrigerant units ice up, so cold commercial spaces need desiccant units.
Use this as a fast starting point, then run your exact space through the calculator above:
| Space size | Humidity control (maintenance) | Water damage / restoration (IICRC S500) |
|---|---|---|
| 2,000 sq ft | 40–70 AHAM pints/day (1 large unit) | 2 LGR units |
| 3,000 sq ft | 70–110 pints/day (1–2 units) | 3 LGR units |
| 5,000 sq ft | 120–180 pints/day (2–3 units) | 5 LGR units |
| 7,500 sq ft | 180–270 pints/day (3–4 units) | 7–8 LGR units |
| 10,000 sq ft | 250–360 pints/day (4–5 units) | 10 LGR units |
Why multiple units beat one giant unit. The IICRC S500 standard sizes drying by airflow across wet materials, not just total pints. Several units positioned around a large space dry faster and more evenly than a single high-capacity unit parked in one corner — and if one fails mid-job, you keep drying. The common restoration rule of thumb is one LGR dehumidifier per 1,000 sq ft for active water damage.
Match the unit type to the job. Standard refrigerant units handle general humidity control above 60°F. LGR (Low Grain Refrigerant) units are required for S500-compliant restoration and pull air below 40% RH. Desiccant units are the choice for cold spaces (below 55°F), freezer ante-rooms, and any job that needs very low grain depression. See all commercial dehumidifiers — LGR, desiccant, and refrigerant, every price shown.
Frequently Asked Questions
What size dehumidifier do I need for a 1,000 sq ft basement?
At moderate humidity (50–60% RH), a 1,000 sq ft basement needs roughly 20–30 pints/day. At very damp conditions (60–70% RH), size up to 30–40 pints. For active water damage or flooding, IICRC S500 guidelines recommend a minimum of 1 LGR dehumidifier per 1,000 sq ft — which typically means a 70-pint commercial unit or larger for aggressive drying targets.
What's the difference between pint rating and actual performance?
AHAM pint ratings are measured at 80°F/60% RH — optimal lab conditions. At real-world conditions (65°F/50% RH), a "70-pint" dehumidifier typically extracts 35–45 pints. This is why restoration professionals size up and why our calculator applies real-world correction factors before showing a recommendation.
When should I use an LGR dehumidifier instead of a standard unit?
LGR (Low Grain Refrigerant) dehumidifiers are required for IICRC S500-compliant water damage restoration. They're more efficient at lower humidity levels and achieve drier air (lower grain-per-pound readings) than standard refrigerant units. Use LGR for: water damage drying jobs, any restoration work where you're billing to a drying standard, or commercial spaces where you need to reach below 40% RH. For general humidity control in a home or office, a standard unit is usually sufficient. We stock LGR dehumidifiers rated for restoration drying.
How many dehumidifiers do I need for a large space?
For spaces over 2,500 sq ft, multiple smaller units distribute airflow better than a single large unit. The IICRC S500 standard recommends calculating dehumidifier placement based on air circulation patterns, not just total capacity. A common restoration setup: one LGR dehumidifier per 1,000 sq ft, positioned to maximize airflow across wet structural materials.
What is a desiccant dehumidifier and when should I use one?
Desiccant dehumidifiers use a silica gel rotor to absorb moisture chemically — they work effectively down to -4°F (-20°C) and don't lose efficiency in cold conditions. Use desiccant units for: cold storage facilities, crawl spaces in winter climates, freezer ante-rooms, or any space below 55°F where a refrigerant unit would ice up or underperform.
Do I need a dehumidifier with a pump?
A built-in condensate pump lets the unit drain continuously to a sink or drain line — no manual emptying. For restoration work or any continuous-operation scenario, a pump is essential. For a crawl space, gravity drain to a floor drain works if the drain is lower than the unit. For a finished basement without a floor drain, a pump is required for hands-free operation.
What size commercial dehumidifier do I need for a 5,000 sq ft warehouse?
For general humidity control in a 5,000 sq ft warehouse, plan on 120–180 AHAM pints/day, usually split across 2–3 units for even coverage. For active water damage or restoration drying, IICRC S500 airflow logic points to roughly 5 LGR units (one per 1,000 sq ft). Ceiling height above 8 ft, very damp conditions, or temperatures below 55°F push you toward the higher end — or toward desiccant units for the cold. For plant-scale coverage, see industrial dehumidifiers for warehouses.
See our full selection of commercial dehumidifiers — LGR, desiccant, and standard refrigerant models. All prices shown. No quote required. Or browse the LGR vs Desiccant guide if you're deciding between types.