Skip to content
Novatek Novastrip Eco-Strip 230V – N120

Novatek Novastrip Eco-Strip 230V – N120

Brand: NovatekSKU: N120Available to order
$3,650.00
Free shipping on this item

Ships from US manufacturer with factory warranty

Request a quote / purchase order

Tell us your quantity, delivery ZIP code and required date. For help choosing equipment, include your application.

Email a quote request Call (978) 295-7538
Planning around a job date? Confirm current availability and delivery timing with us before ordering.
Authorized Novatek dealerGenuine Novatek equipment with full factory warranty support
Tax-exempt & PO acceptedSend your exemption certificate and we bill without sales tax
30-day returnsUnused equipment in original packaging, within 30 days
Ordering 3+ units? Call for volume pricing – +1 (978) 295-7538
Ach Direct DebitAmazon American Express Apple Pay Diners ClubDiscoverGoogle Pay Mastercard PayPalShop Pay USDC Visa

Need help choosing? Talk to an expert

+1 (978) 295-7538

Novatek Novastrip Eco-Strip 230V: Compact Infrared Tile Removal for Tight Spaces

The Novatek Eco-Strip (N120) is the 230V build of Novatek's smallest infrared tile heater. It sits over the floor and uses radiant heat panels to warm the tile and the adhesive beneath it, so the bond releases and the tile lifts intact. No water, no solvents, and no chipping or grinding, which keeps a vinyl asbestos tile (VCT) job in a non-friable state. At 18 lbs it carries into closets, stairwells, and small rooms where larger machines do not fit.

Why Abatement and Flooring Crews Run the Eco-Strip 230V

Asbestos VCT abatement penalizes dust. Chiseling, scraping, and grinding break tile into airborne fragments; the Eco-Strip avoids that by heating the floor until the tile and mastic separate on their own. Crews lift whole tiles into disposal bags, then move the machine to the next 12" x 12" section. The 230V configuration draws 10 amps, half the current of the 115V build, which suits sites already wired for 220/240V service.

  • Releases tile and adhesive with radiant heat alone, so no water or chemical softeners enter the work area
  • Lifts vinyl asbestos tile intact in a non-friable state, cutting the dust that chipping and grinding create
  • 196 square inch heat-panel footprint covers one 12" x 12" tile per heating cycle
  • Runs on 220V, 10 amp service, matching crews already set up for 230V power
  • Weighs 18 lbs and reaches into closets, stairs, and small rooms a larger stripper cannot
  • Ceramic emitter strips are individually replaceable, so a worn strip does not retire the whole panel
  • Safety sensor shuts the machine down if it is left unattended

Eco-Strip 230V Applications and Environments

Asbestos floor-tile (VCT) removal in closets, stairwells, and confined rooms, adhesive and mastic softening ahead of resurfacing, and abatement and flooring demolition where space is too tight for a mid-size or full-width stripper.

Specifications

Part Number N120
Voltage 220V
Amperage 10 Amp
Heat Panel Footprint 196 square inches (16" x 16")
Pad Size 14" x 14" (350 mm x 350 mm)
Tile Removal per Cycle 1 x 12" x 12" tile
Weight 18 lbs (8 kg)
Height 35" to 44" (87.5 to 110 cm)
Heating Method Infrared radiant heat, replaceable ceramic emitter strips
Construction Aluminum

Documents

Manual

Product Warranty Information

"180 Days"

B2B & Tax-Exempt Purchases

We supply contractors, restoration companies, property managers, schools, government agencies, and other tax-exempt organizations.

How to place a tax-exempt order:

  1. Write to us through our Contact Us page or email info@uscleaningtools.com and attach your valid tax exemption certificate (state resale or exemption certificate).
  2. We verify your certificate and mark your account tax-exempt — usually within one business day.
  3. Place your order and sales tax will not be charged.

For volume pricing or purchase orders, call +1 (978) 295-7538.

Shipping & Returns

Free shipping on most brands for orders over $300, delivered to the lower 48 states. Any brand-specific freight rate is shown at checkout before you pay.

Processing & delivery: in-stock orders are processed within 1–2 business days and typically deliver in 5–7 business days. Tracking is emailed within 24 hours of shipment. Built-to-order and backordered equipment shows its lead time on this page.

Freight deliveries: inspect your equipment on arrival and note any damage on the delivery receipt. Items damaged in transit or defective on arrival are fully covered at no cost to you.

Cancellations: cancel any time before your order ships. Refunds are issued for the order total minus a non-refundable payment processing fee, which may apply, so a cancellation is not always a 100% refund. No fee is deducted if we cancel the order or the item arrives damaged or defective.

30-day returns: return unused equipment in its original packaging within 30 days of delivery. Change-of-mind returns are subject to a restocking fee. To start a return, email info@uscleaningtools.com or call +1 (978) 295-7538.

Product Image
Added to cart
Novatek Novastrip Eco-Strip 230V – N120Novatek Novastrip Eco-Strip 230V – N120
View Cart
$3,650.00

Frequently Asked Questions

How does infrared tile removal work?
The Eco-Strip sits over the floor and its panel emits infrared radiant heat that penetrates the tile and warms the adhesive underneath. As the bond softens, the tile releases and lifts intact. Each cycle covers a 196 square inch footprint, or one 12" x 12" tile, then the machine moves to the next section.
Why does it use no water or chemicals?
The machine releases tile through heat alone, so there is no need for water, solvent softeners, or adhesive removers. That keeps the work area dry, avoids chemical fumes, and leaves no slurry to clean up or dispose of.
Is the Eco-Strip safe for asbestos VCT removal?
Heat-release keeps vinyl asbestos tile in a non-friable state. Because the tile lifts whole instead of being chiseled or ground, the process avoids the airborne dust that breaking tile creates. A safety sensor also shuts the machine down if it is left unattended.
What power does the 230V N120 require?
The N120 runs on 220V at 10 amps. The 115V version of the same machine draws 15 amps, so the 230V build halves the current draw and suits sites already wired for 220/240V service.
What is the coverage rate?
The heat panel has a 196 square inch footprint and releases one 12" x 12" tile per heating cycle. Crews lift the tile, then reposition the machine over the next tile.
How does the N120 differ from the N379 in size?
The N120 Eco-Strip has a 196 square inch footprint (16" x 16") and weighs 18 lbs, built for closets, stairs, and confined rooms. The N379 Novastrip has a larger 378 square inch footprint (16" x 28"), removes two 12" x 12" tiles per cycle, and weighs 45 lbs for larger floor areas.