Skip to content

Free Shipping on Most Orders

Orders over $300 ship free to the continental US. Threshold may vary by brand.

Expert Support

Talk to a specialist — not a call center.
+1 978-295-7538

30-Day Returns

Not the right machine? Return or exchange within 30 days, no hassle.

Authorized Dealer

30 pro brands sold direct. Full manufacturer warranties honored.

Monitoring

Air quality monitoring and safety equipment for abatement and remediation. Differential pressure monitors and room pressure displays verify negative air containment integrity during asbestos, mold, and lead removal operations. Used by environmental abatement contractors, industrial hygienists, and remediation project managers who need real-time containment documentation for OSHA and EPA compliance during hazardous material removal projects.

Original price $1,277.50 - Original price $1,277.50
Original price
$1,277.50
$1,277.50 - $1,277.50
Current price $1,277.50

Abatement Technologies RPM-RT1 Room Pressure Monitor – ±0.10 inWC, BACnet, 24V

Abatement Technologies
In stock

Wall-Mounted Differential Pressure Monitor for Isolation Rooms and ICRA Construction Zones The Abatement Technologies RPM-RT1 is a wall-mounted dif...

View full details
Original price $1,277.50 - Original price $1,277.50
Original price
$1,277.50
$1,277.50 - $1,277.50
Current price $1,277.50
Original price $1,478.50 - Original price $1,478.50
Original price
$1,478.50
$1,478.50 - $1,478.50
Current price $1,478.50

Abatement Technologies PPM3-S Pressure Monitor – ±0.1" WC, 16-Day Battery

Abatement Technologies
In stock

Continuous Isolation Room Pressure Monitoring: Abatement Technologies PPM3-S Manometer The Abatement Technologies PPM3-S Portable Differential Pres...

View full details
Original price $1,478.50 - Original price $1,478.50
Original price
$1,478.50
$1,478.50 - $1,478.50
Current price $1,478.50

Professional Pressure Monitors for Critical Environment Control

Maintain precise differential pressure in containment zones, healthcare isolation rooms, and cleanrooms with our professional-grade pressure monitoring equipment. These Abatement Technologies monitors provide real-time pressure verification essential for regulatory compliance and occupant safety during remediation, construction, and healthcare operations.

Pressure Monitors: Real-Time Differential Pressure Verification

Differential pressure monitoring confirms that containment barriers function as designed. During mold remediation, asbestos abatement, and lead removal projects, negative air pressure prevents contaminated particles from escaping work areas into occupied spaces. Our monitors display pressure differentials continuously, alerting operators immediately when conditions fall outside specified parameters.

Healthcare facilities rely on differential pressure to maintain isolation room integrity. Airborne infection isolation rooms require negative pressure relative to corridors, while protective environment rooms for immunocompromised patients require positive pressure. Accurate monitoring ensures patient safety and regulatory compliance with CDC and Joint Commission requirements.

Wall-Mounted vs Portable Monitoring Solutions

The RPM-RT1 Single Room Pressure Monitor mounts permanently for continuous monitoring in healthcare settings, cleanrooms, and laboratories requiring ongoing pressure verification. Wall-mounted installation provides 24/7 monitoring without setup time, ideal for facilities with dedicated isolation or containment rooms.

The PPM3-S Portable Differential Pressure Monitor offers flexibility for remediation contractors and consultants working across multiple job sites. Portable design allows rapid deployment for project-based monitoring, temporary containment verification, and HVAC system diagnostics. Battery operation enables monitoring in locations without convenient power access.

Applications Requiring Pressure Monitoring

Restoration and remediation professionals use pressure monitors to document containment effectiveness throughout projects. Continuous monitoring records demonstrate compliance with IICRC S520 mold remediation standards, EPA asbestos work practices, and OSHA lead exposure requirements. Documentation protects contractors from liability disputes regarding containment integrity.

Construction dust control increasingly requires verified negative pressure in occupied building renovations. Pressure monitoring confirms that construction barriers prevent dust migration into occupied tenant spaces, meeting building management and lease requirements for interior construction projects.

Browse our selection of professional pressure monitoring equipment. Air scrubbers and negative air machines create the pressure differentials these monitors verify. Contact our equipment specialists for application guidance on monitoring requirements for your specific projects.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare