Introducing the Abatement Technologies HEPA-AIRE H1990M Negative Air Machine: Your Go-To for Fresh, Safe Air!
The Challenge of Confined Spaces
Keeping air quality in small or tough areas ain't simple. That's where the HEPA-AIRE H1990M Negative Air Machine from Abatement Technologies comes in - a petite yet mighty contraption that ensures pristine air without sacrificing effectiveness or mobility!
High-Performance Air Filtration
The H1990M offers versatile airflow, ranging from 1,050 to 1,600 CFM, making it suitable for various environments. At its heart is a 99.97% certified HEPA filter, which effectively captures particles as small as 0.3 microns. Whether you're tackling dust, mold, or airborne contaminants, this precision-engineered machine ensures consistently clean air for safer workspaces.
Compact and Lightweight Design
Weighing just 125 pounds (including filters), the H1990M is built for mobility. Its slim profile fits seamlessly into tight spaces where bulkier machines fall short, making it the ideal choice for confined or hard-to-access areas.
Durable and User-Friendly Construction
Engineered for longevity and ease of use, the H1990M features a 20-gauge galvanized steel cabinet with watertight pop rivet construction. The swing-out hinged door with cam latches allows for quick and hassle-free filter replacements, while the 12-inch exhaust collar simplifies connection to flex ducts for straightforward installation.
Certified Safety and Reliability
Built to meet rigorous standards, the H1990M is NRTL-certified and complies with UL and CSA safety regulations. Its motor includes thermal overload protection, ensuring safe and reliable performance even during extended operation.
Perfect for Confined and Challenging Environments
Designed for a variety of applications, including healthcare, construction, and remediation, the HEPA-AIRE H1990M excels in removing dust, mold, and airborne contaminants. Its compact, durable design ensures it performs efficiently, even in the most demanding settings.
Key Features of the Abatement Technologies H1990M
-
Two Operating Speeds: Airflow settings of 1,600 CFM (high) and 1,050 CFM (low) allow you to tailor performance to your specific needs.
-
Certified HEPA Filtration: The HEPA filter achieves 99.97% efficiency at 0.3 microns, ensuring excellent air purification.
-
Lightweight and Portable: Weighing only 125 pounds, the H1990M is easy to transport and maneuver, ideal for tight or confined spaces.
-
Durable Construction: A 20-gauge galvanized steel cabinet ensures lasting performance in tough conditions.
-
Easy Filter Maintenance: The swing-out door with cam latches simplifies filter replacements, reducing downtime.
-
Reliable Motor and Blower: A 1 hp motor with thermal overload protection ensures consistent and safe operation.
-
Certified Safety: Complies with stringent UL and CSA standards, providing peace of mind in any work environment.
Invest in the Compact Power of the H1990M
When air quality matters, the Abatement Technologies HEPA-AIRE H1990M delivers unmatched performance in a lightweight, durable, and easy-to-use package. Whether you’re in a healthcare facility, a construction site, or tackling tough remediation projects, this negative air machine ensures cleaner, safer air in the spaces that need it most.
Specifications
| Feature |
Specification |
| Dimensions (L x W x H) |
89.212 x 48.578 x 76.835 cm (35.125" x 19.125" x 30.25") |
| Airflow |
1,600 (H), 1,050 (L) |
| Net Weight With Filters |
125 lb |
| Shipping Weight |
141 lb |
| Power Supply Requirements |
120 VAC, 60 Hz, 15 A |
| Cabinet Material |
20 Gauge Galvanized Steel |
| Pre-Filter Access |
Swing-out hinged access door |
| Stage 2 Pre-Filter |
2" pleated particulate pre-filter (H1902) |
| Stage 1 Pre-Filter |
1 coarse particulate polypad pre-filter (H1901) |
| Final Stage HEPA Filter |
Tested and certified to 99.97% efficiency or higher for 0.3 micron particles (H1910M) @ 2000CFM |
| Motor Blower |
1 hp, 60 Hz, Single Phase |
| Amperage |
9 A or less |
| Optional Second Stage Pre-Filter |
2" high-capacity carbon filter (VL2002) |
| Automatic Restart |
Yes |
| Carrying Handles |
Yes |
| Casters |
4, removable (2 fixed, 2 locking swivel) |
| Thermal Overload Protection |
Yes |
| Certifications |
UL and CSA |
Documents
HEPA-AIRE H1990M Negative Air Machine
HEPA-AIRE H1990M Negative Air Machine
Frequently Asked Questions
What is the CFM rating of the Abatement HEPA-AIRE H1990M Negative Air Machine?
The Abatement HEPA-AIRE H1990M Negative Air Machine is designed for professional containment applications with variable speed control. The specific CFM (cubic feet per minute) varies by speed setting. At maximum speed, Abatement negative air machines typically deliver between 1,000-2,000 CFM depending on the model. This unit features a powerful motor with multiple speed settings to accommodate different containment sizes and pressure requirements, ensuring effective air filtration and negative pressure control.
Can this negative air machine be used for asbestos abatement projects?
Yes, the Abatement HEPA-AIRE H1990M Negative Air Machine is specifically engineered for asbestos abatement and other hazardous material containment projects. It features true HEPA filtration (99.97% efficient at 0.3 microns), which meets or exceeds OSHA and EPA requirements for asbestos abatement work. The unit includes a sealed filtration system to prevent contaminated air bypass and is designed for continuous duty operation in demanding abatement environments.
How often do I need to replace the HEPA filters on this unit?
HEPA filter replacement frequency depends on usage intensity and environmental conditions. For typical abatement projects, the final stage HEPA filter should be inspected after each major project and replaced when the pressure differential indicator shows high resistance or after approximately 2,000-3,000 hours of operation. Pre-filters should be changed more frequently (every 500-1,000 hours) to extend HEPA filter life. Always inspect filters before starting a new project.
Does the Abatement HEPA-AIRE H1990M Negative Air Machine include a manometer for pressure monitoring?
The Deluxe "A" models (with MA suffix) include an integrated manometer for real-time static pressure monitoring. Standard models can be equipped with optional external pressure monitoring devices. A manometer is essential for maintaining proper negative pressure in containment areas and ensuring compliance with abatement standards. Many contractors add the optional RPM-RT1 room pressure monitor for automated monitoring and data logging.
What power requirements does this negative air machine have?
The Abatement HEPA-AIRE H1990M Negative Air Machine operates on standard 115V/60Hz power with a dedicated 15-20 amp circuit recommended depending on the model. The unit features a hospital-grade power cord and plug for reliable, safe operation. For jobsites without adequate power, the unit can run on a properly sized generator (minimum 3,500 watts recommended). Always ensure adequate power supply to maintain consistent negative pressure throughout the project duration.