{"product_id":"mi-t-m-mh-0190-0m11","title":"Mi-T-M MH-0190-0M11 Kerosene Forced-Air Heater – 190,000 BTU, 4,750 Sq Ft, Multi-Fuel","description":"\u003ch2\u003eMH-0190-0M11 Kerosene Forced-Air Heater for Warehouses\u003c\/h2\u003e\n\u003cp\u003eThe Mi-T-M MH-0190-0M11 produces 190,000 BTU to heat about 4,750 square feet, sized for warehouses and large open structures. It runs on kerosene, diesel, fuel oil, JP8, or Jet A with a digital thermostat for steady output.\u003c\/p\u003e\n\u003ch3\u003eMH-0190-0M11 Heat Output and Fuel\u003c\/h3\u003e\n\u003cp\u003eA 1\/2 HP motor pushes 409 CFM and the 13.2-gallon tank runs about 10 hours.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e190,000 BTU across ~4,750 sq ft\u003c\/strong\u003e — heats a warehouse or large workshop\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-fuel (kerosene, diesel, fuel oil, JP8, Jet A)\u003c\/strong\u003e — run on available fuel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital thermostat with error read-out\u003c\/strong\u003e — hold temperature, read faults\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSure-Start dual-connector ignition\u003c\/strong\u003e — starts in the cold\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel gauge\u003c\/strong\u003e — see runtime remaining\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverheat and flame-out shutoff\u003c\/strong\u003e — safe shutdown on fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMH-0190-0M11 Applications and Environments\u003c\/h3\u003e\n\u003cp\u003eWarehouses, construction sites, and agricultural buildings use the MH-0190-0M11 for temporary winter heat in ventilated areas. It runs on 120V at 2.5 amps, is CSA C-US certified, weighs 62 pounds, and carries a one-year warranty. Ventilate per fuel-burning heater requirements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKerosene\/Multi-Fuel Forced Air\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,750 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e409 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP, 120V\/60Hz, 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Tank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.2 gal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.37 gph\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSure-Start dual-connector\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermostat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverheat + flame-out shutoff\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 x 17 x 22 in\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C-US\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0651\/8112\/2717\/files\/Kerosene-Forced-Air_Mi-T-M.pdf?v=1783027653\"\u003eMi-T-M MH-0190-0M11 Specification Sheet (PDF)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0651\/8112\/2717\/files\/37-1522_MH-0075_0135_0190_0215-0M11-E-F-S.pdf?v=1783027655\"\u003eMi-T-M MH-0190-0M11 Owner's Manual (PDF)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Mi-T-M","offers":[{"title":"Default Title","offer_id":48565708914845,"sku":"MH-0190-0M11","price":885.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/8112\/2717\/files\/MH-0190-0M11.webp?v=1783027874","url":"https:\/\/uscleaningtools.com\/products\/mi-t-m-mh-0190-0m11","provider":"US Cleaning Tools","version":"1.0","type":"link"}